袁
袁明刚1529
2026-09-09
微板法试剂盒就是设计给酶标仪用的,可以直接加样后上机。注意波长按说明书设,通常葡萄糖、乳酸在540-570 nm左右,有些试剂盒要求双波长或终点法,不要自己改。加样时先加标准品和样品,再统一加工作液,避免时间差。用排枪能减少孔间误差。标准曲线每板都做,不建议跨板共用。读数前检查孔内有无气泡,轻震混匀。如果你用的是带动力学功能的酶标仪,可以按说明书做动力学法,比终点法更不易受底色影响。
P
PCR5964
2026-09-17
DMEM上清含血清和酚红,测葡萄糖和乳酸一般来说可以直接做,但前提是离心去除细胞和碎片,避免浊度干扰。酚红对大多数葡萄糖和乳酸酶法试剂盒干扰不大,不过有些终点法在碱性条件下颜色会叠加,最好设未培养的完全培养基做空白对照。如果样品中蛋白很多或试剂盒灵敏度高,可以用10 kDa超滤管除蛋白,但常规培养上清不一定需要。先做预实验:取原液和稀释后样品各测一次,看是否平行。若有偏差再考虑除蛋白或增加样品空白。
B
Bio5412
2026-09-09
DMEM本身葡萄糖含量约4.5 g/L(25 mM),培养后根据细胞密度可能消耗很多;乳酸则升高。上清直接测很可能超出线性,建议先稀释。葡萄糖可做1:5-1:20,乳酸做1:2-1:10,具体要看你细胞类型和培养时间。最好先测一个未培养DMEM和几个培养上清原液,再决定正式稀释倍数。稀释液用PBS或试剂盒提供的稀释液,不要用水直接稀释,渗透压变化可能影响酶反应。稀释后的结果乘以倍数,同时扣除未培养培养基背景,避免把基础葡萄糖算成消耗量。
小
小小老张7405
2026-09-11
含酚红和血清的DMEM有时会使终点法背景偏高,建议做样品空白孔:样品加不含启动试剂的工作液,或样品加终止液,观察是否有非特异显色。如果背景高,可以尝试超滤或改用酶法试剂盒,酶法特异性较好。乳酸试剂盒要确认是L-乳酸氧化酶,因为细胞主要产L-乳酸。另一个常见问题是高浓度葡萄糖可能对乳酸检测产生交叉干扰,如果发现不成线性,可以增加稀释。若时间紧,也可以用葡萄糖/乳酸分析仪或生化分析仪代测,但微板法适合大批量。
R
ReagentTech
2026-09-17
复孔方面,标准品建议2-3个复孔,样品至少2个复孔,如果样品量大且加样稳定,2个复孔基本够;但有条件就3个,可以剔除异常值。每板放一个未培养的DMEM完全培养基作为质控品,看板间差异。96孔板不要全部排满,留几个孔做空白或QC,避免边缘效应。加样量少时边缘孔容易受温度影响,可以用封板膜或把边缘空置。葡萄糖和乳酸检测如果样品稀释不当,容易复孔CV变大,这时先检查稀释操作和枪头一致性。