To determine the fat content in animal liver, should analytical grade or chromatographic grade chloroform be used?

Medical Devices
Asked by:LisaAssay4714 2026-06-01 Views 272 4 answers
Back to List ✏️ Ask a Question
💡 How to Answer This Question
  1. 1
    Read the Context

    Read the full description, category and tags to understand the real scenario.

  2. 2
    Give an Actionable Answer

    Give concrete steps, cautions and reasoning — not just a conclusion.

  3. 3
    Cite Sources

    Reference standards, papers or product manuals to make the answer more credible.

  4. 4
    Wait for Acceptance

    You will be notified if accepted. Continue the discussion in comments.

Tags:

All Answers4
谢
谢小小 2026-07-03
能不能用分析纯,关键不是‘脂肪提取’这四个字,而是你的检测方法允许多大杂质。鸡肝脏脂肪含量通常在百分之几,索氏或氯仿-甲醇法后续多是旋转蒸发、烘干称重,杂质在这类方法里影响有限。建议用分析纯先做方法空白、基质加标和一批实际样品,与色谱纯或原进口批次做平行比对。如果空白残渣远低于方法定量限,加标回收和重复性在你实验室SOP允许范围内,分析纯就足够。不要单看纯度标签,要看批次COA的实际数据。
S
Sample 2026-09-16
你一次60个样品用量不算小,进口货期两周很误事。国产分析纯氯仿现货基本可以覆盖,像国药、西陇、阿拉丁、麦克林都有包装。500ml一瓶做60个样品可能偏小,建议直接问2.5L或4L规格,单价会划算些,但别一次性囤太多,氯仿存放时间久要关注稳定剂。让供应商提供COA,重点看乙醇稳定剂含量和蒸发残渣。询价时把‘分析纯、含稳定剂、现货’三个条件说清楚,不同渠道价差可能在包装和运输上,具体成交价以当天询价为准。
徐
徐佳艳 2026-09-20
做动物肝脏脂肪含量,氯仿-甲醇法经典的Folch或Bligh-Dyer,提取阶段主要靠溶剂极性和分配,不是上色谱检测,分析纯氯仿通常能满足。色谱纯的差异在于杂质更少、紫外吸收低,但脂肪称量或化学法检测对这类杂质不敏感。我更关注氯仿的蒸发残渣、水分和游离氯指标,这几个会影响空白和提取稳定性。建议到货后做一次空白提取和加标回收,跟旧批次比对,如果空白低、回收在方法允许范围,就放心用分析纯。若后续要进色谱,再单独评估溶剂峰。
T
TubeMax1870 2026-09-17
动物肝脏含水高,氯仿-甲醇法提取脂肪时,样品量2g、60个,溶剂用量会很大,通风橱和废液回收不能省。分析纯做提取没有问题,但操作上建议先把组织用甲醇匀浆,再加氯仿,最后调比例到氯仿-甲醇2:1,分层更干净。提取过程别用普通塑料离心管密封长时间震荡,氯仿会溶胀垫片,选聚四氟乙烯复合垫。如果对纯度不放心,可以做一组平行用色谱纯对比,若脂肪含量差异很小,后续就固定一个国产品牌批次,避免不同批次混用。