Can phosphorylated protein microarrays use RIPA to lyse cells? Will the background be very high?
Storage & Shipping
💡
How to Answer This Question
-
1
Read the Context
Read the full description, category and tags to understand the real scenario.
-
2
Give an Actionable Answer
Give concrete steps, cautions and reasoning — not just a conclusion.
-
3
Cite Sources
Reference standards, papers or product manuals to make the answer more credible.
-
4
Wait for Acceptance
You will be notified if accepted. Continue the discussion in comments.
All Answers3
质
质控老手6942
2026-09-19
RIPA usually contains 0.1% SDS, which is fine for WB, but many protein arrays (especially phospho-arrays) are sensitive to SDS and ionic strength, which can easily interfere with spotting antibody binding and increase background. I recommend prioritizing the lysis buffer from the manufacturer's kit, or preparing a mild SDS-free lysis buffer (e.g., containing 1% NP-40, 150 mM NaCl, Tris pH 7.5), supplemented with fresh phosphatase inhibitors and protease inhibitors. For adherent cells, lyse directly in the plate; for tissue, first mince and homogenize, then centrifuge at 4°C and collect the supernatant. If RIPA must be used, first test a single array on a small scale to check the background—don't run the full set right away.
E
Elisa6223
2026-09-08
Loss of phosphorylation signal is mostly not due to the chip itself, but rather insufficient suppression of phosphatases between lysis and loading. Experience shows: prepare lysis buffer fresh immediately before use, add phosphatase inhibitor Cocktail at a sufficient 1× concentration, and optionally supplement with 1 mM Na3VO4 and 1 mM NaF; perform all operations on ice, and avoid repeated freeze-thaw cycles for tissue samples. Quantify immediately after lysis; protein concentration generally needs to be 0.5–2 mg/mL, and prepare 20–50 μg total protein per array/well, with the volume according to the instructions. Do not boil and denature before loading; many chips require non-denaturing conditions. Run a pilot experiment: use serum starvation/stimulation control lysates to run a small chip and confirm the signal window.
S
Sam3133
2026-09-15
Common causes of high background: excessive protein loading, residual SDS, insufficient blocking, and inadequate washing. It is recommended to first set the protein concentration at around 1 mg/mL, quantify with BCA, and do not exceed 2 mg/mL; after centrifuging the lysis buffer, collect the supernatant to avoid interference from viscous genomic DNA, and shearing can be performed by sonication or passing through a 26G needle. Use the blocking solution recommended by the manufacturer, do not skip the room-temperature blocking time, and use a shaker for membrane/well washing. For phosphorylation arrays, it is best to perform stimulated/unstimulated conditions in the same batch, and normalize to a total protein array or housekeeping proteins on the same array. If the background remains high, serially dilute the samples to find the loading amount with the best signal/background ratio.